Summary | flab fix on server shutdown detection |
Platform | Unix |
Category | bugfix |
Requires | |
Client Required Patch/es | |
Supersedes | 518, 516, 513, 512, 506, 505, 503, 499 |
Superseded by | 528 : Cancelled / Not hidden |
Affects | Server: License Analyzer |
Last Updated | February 24, 2011 |
FLAB: A bug resulted in false detection of license server shutdown, causing some license usage to be dropped.
flab now accepts the option "-d <prod-list>", where <prod-list> is a comma separated list (without space) with names of products. Old flab data for these products will be deleted. filtrator will now reset all licenses in use to zero when a "SHUTDOWN request" is read from the flexlog file.
Fixed bug causing events at 0:00:00 to be counted twice. License clients, flexlogcollector.
Sometimes when filtrator processed OUT + IN usage across GMT midnight, data could be missing. This has now been fixed for these platforms: NOTE: The AIX4.2 binary will not be included.
When processing FLEXlm debug data, a weakness in the sorting algorithm caused certain events to occur out of order, resulting in incorrect usage reported. This has now been fixed. NOTE: The AIX4.2 binary does not support FLEXnet debug log data.
Will now include debug events occurring after license server startup but prior to first flexpoller/flab event. (These debug events would previously be ignored.)
Corrected mapping to local time in stead of GMT.
Fixed bug in FlexLog Archive Builder which sometimes caused usage to be lost when license daemon was shut down.
Fixes bug in prime time correction of licpoll data in filtrator.
Unpack tar file in e.g /tmp/patch on the Open iT server. Do the following as root: cd /tmp/patch ./patch.pl